Fixed Gas Monitors 2620 (Weather Proof)

FIXED-GAS-MONITORS 2620 (WEATHER PROOF)FIXED-GAS-MONITORS 2620 (WEATHER PROOF)

Fixed Gas Monitors 2620 (Weather Proof)

The ENDEE Model 2620 Fixed Gas Monitor is a rugged field-mounted monitor for continuous measurement of toxic gases, hydrocarbons, and oxygen in process environments, flue gases, or ambient air. Its durable construction, combined with application-specific sensors and configurable alarms, ensures fast, accurate, and uninterrupted gas detection for industrial and commercial applications.

Category:

The ENDEE Model 2620 Fixed Gas Monitor is a rugged field-mounted monitor for continuous measurement of toxic gases, hydrocarbons, and oxygen in process environments, flue gases, or ambient air. Its durable construction, combined with application-specific sensors and configurable alarms, ensures fast, accurate, and uninterrupted gas detection for industrial and commercial applications.

Special Features
  • Weatherproof or explosion-proof enclosure for harsh environments
  • Fast and accurate gas detection with long-life sensors
  • Independent, user-adjustable alarm levels
  • Fail-safe protection to monitor input power and amplifier status
  • Flexible sensor mounting options for versatile installation
  • Recorder output for data logging or analysis
Applications
  • Industrial processing plants
  • Flue gas analysis in exhaust systems
  • Chemical plants and production areas
  • Ambient air monitoring in industrial spaces
  • Oil & Gas exploration, refining, and storage facilities
  • Power plants for environmental compliance and safety

Sensor Technologies

The HEART of any Analytical system is the SENSOR. It is the most critical component in overall system performance. Because no single sensor technology is ideal for all applications, ENDEE offers TEN different sensor technologies.

This capability is mandatory in today’s complex industrial market. Command of each of these technologies enables us to “FITTHE PRODUCTTO THE APPLICATION”, and assure long-term service and reliability & optimal performance in every application.

Specification

Minimum Resolution0.1 or 1 unit of the range.
IndicationDigital Continuous
MountingWall
Sensor TechnologyAppropriate to Application
Detection MethodDiffusion / Sample Draw Pump
Accuracy±2%
Linearity±2%
Relative Humidity0 – 99% Non-condensing
Response Time(90% in 10 seconds)
Signal Output Recorder0-IV, 4-20 mA (Optional)
Alarm SettingHigh and Very High Adjustable over full range
Alarm CircuitsSPDT 5 AMP 220V Contacts
ControlsZero, Span, Alarm Setting
Power Source110V or 220V 50 Hz. 24 VD C (Optional)
DimensionsModel 2620 – 250 X 200 X 100mm

Gas Specification

GasesRangesGasesRanges
Hydrogen0- -100 to 2000 PPMHydrogen Sulphide0-5 to 2000 PPM
Chlorine0- • 3 to 2000 PPMNitric Oxide0-100 1000 PPM<
Bromine0- • 3 to 2000 PPMNitrogen Dioxide0-30 to 100 PPM
Fluorine0- •1 to 10 PPMAmmonia0-300 PPM
Hydrogen Chloride0- •5 to 15 PPMOrg. Solvents/VapoursDepending on Solvents
Hydrogen Fluoride0- • 5 to 15 PPMOxygen0 – 30% to 100%
Hydrogen Cyanide0 •10 to 100 PPMLPG/CNG/H20-100%LEL
Carbon Dioxide0- • 05% to 20%Combustible Gases0 -100% V/V
Sulphur Dioxide0- •10 to 2000 PPM