Products/ Portable Gas Monitors
Special Features
Portable Keychain Size.
Range 0 – 500 PPM.
Carry Everywhere.
Single Button for ON-OFF, Viewing Dosimetry, Logging Event.
Real time PPM CO Display Updated Every 5 Seconds.
Loud Buzzer, Bright LED, Vibration Alerts.
Real time ppm CO display updated every 5 seconds .From 0-500ppm level readings warns users of TRUE
LEVELS of CO which can cause a multitude of physical and metal symptoms such as delayed or s low
responses, nausea, mild headaches, and sleepiness
Portable key chain size weight less than one ounce and can travel and attach everywhere, why not own carbon
monoxide protection that doesn't stop at the door but can be used every where you go, travel, and sleep?
Easy to use one button operation .Two models of
Model CO 300
operation, 12 hour and always on.
Alarms three ways at three levels. Loud buzzer , Bright LED ,Vibrator alert at three pre-set carb on
monoxisde levels, you will know when to act to prevent CO poisoning.
2 year Warranty, Best Industry Price Dosimetry calculations include Time Weighted Average (TWA), Total 1 Exposure , and Maximum Exposure
Why buy a limited life detector when you can own Pocket CO with user replaceable battery.
sensor. Easy user calibaration
Specifications
Display
Digital LCD with Back Light in Increments of 1 ppm
Sampling Method
Gaseous Diffusion
Response Time
<90 seconds to 90%
Size
67.6 x 35.6mm x 15.5 mm
Alarms
(82 dB Buzzer@24in,
LED, Back light Vibrator)
Operational First Alarm at or above 50 ppm, Second alarm at or above 125 ppm, Third alarm at or above 400 ppmHourly warning when CO above the 8- hour 25PPM ACGIH TWA
Temperature above 50 C/ 125 F : "HOT" Displayed
Temperature below 0 C/32 F : "COLD" Displayed
Low Battery Warning : "BATT" Displayed
Sensor
Transducer Technology T-Series Electrochemical
Period Of Operation
"12 Hour" and Always On"
Dosimetry
(12 Hour Detection Period Only)
Calculate and Records : Maximum Exposure (ppm), Time of Max Exposure (minute since turned on), Total Exposure in ppm / Hours,
8 hour Time Weight
Test
Self-Test on Startup Checks Circuitry, Alarms, Battery and
Operating Temperature. Does not check sensor
Battery Information
Battery Check on Startup and During Operation. User Replaceable CR 2450
Operating Temp
0-45 C Displayed, Readings Automatically Compensated
Pressure Effects
Reading decreases with Decreasing Pressure, Down 70% at 10,000 fts
Humidity Limits
15-85 % RH, Non-condensing
Calibration
Recommended at least lx per year, or when ever accuracy of reading is
Critical
User Interface
Single Button operation
Interferences
Non significant, Except Hydrogen
Warranty
Two Years (Excluding Battery)