Portable Gas Analysers
Products/ Portable-Gas-Analyzers
MOdel 84
Special Features
  • Complete Automatic operation Complete Automatic operation includinc Calibration, "ON - OFF" & "SAMPLE" Keys only.
  • Self diagnostic check Self diagnostic check & specific fault indication, Discrete LEDs for Sample Flow, Sensor Efficiency & Battery Condition.
  • Self-integrity Check Continuous on-line full self-integrity check eliminates wrong measurements due to Instrument Faults.
  • USER Friendly Visual Messages on status on functioning.
  • Proven Sensor Technology Special purpose long life Sensors with Cross Interference filters to achieve high accuracy.
  • Oxygen Sensor Guaranteed for 4 years.Display of Concentrations Continuous, Stable & Automation display
  • Model 84
    Model PA 960
    of concentrations - ensures maximum accuracy & reliability.
  • Sensor Technologies Analyser is built up using sensors technology to suit specific application.
  • Batteries Long life rechargeable batteries.
  • Diffusion or Suction with Time tested, sturdy, high suction in-built pump supervisory circuit continuously monitors the pump against failure.
  • Disposable Cartridge Line Filter & Moisture Separator Low porosity, disposable cartridge line filter & moisture separator suitably conditions the sample.
  • Calibration A built-in procedure allows easy and automatic span sensor calibration using stand; 3rd gas cylinder. Periodic zero calibration is automatic on demand.
  • Electronic Flow Meter An automatic built-in system measures a flow of sampling gas to obtain a constant sampling volume.
  • Multi Fuel Selection The fuel efficiency analyser can be programmed for selection upto 10 fuels for calculating combustion values.
  • Gas Probes & Sampling System Flue gas sampling probes with different lengths, shapes i and max, operating temperatures Upto 1600°C are available to match various requirements of different applications. A sintered pre-filter is suggested for severe and having dust loded applications.
  • Heated Sampling Hose A heated sampling Hose is available for high temperature applications. A heated hose allows flue gas sampling without condensation.
  • Continuous Monitoring The industrial design and the advanced technology applied to the unit, allows it to perform long term gas analysis
  • PROBES - APPLICATION SPECIFIC AVAILABLE Ambient CO Probe An optional probe to monitor ambient CO concentration to keep the operator in a safe environment.
  • Gas Sniffer Probe To detect and locate the precise position of a gas leak in a pipe network or equipment.
  • Smoke Index Smoke Index measurement can be obtained using a specia 1 heated probe, supplied on request, and through a dedicated internal procedure that computes the required volume of gas sample flowing into the specific filter. The results can be obtained by comparison with the Smoke Index Table.
  • Gas Velocity An internal procedure allows gas velocity measurements using the differential pressure inlet combined with a pitot tube.
  • Report of Calibration Each instrument is factory calibrated and certified against Endee's Standard Gasses and shipped with a Report of Calibration stating the nominal and actual values and the deviation error.
  • Quality System Research, development, production, inspection and certification activities are defined by methods and procedures of the Endee's System inspected for compliance and certified ISO 9001.
  • Specifications
  • Display
  • High quality Alpha Numeric LCD.
  • Calibration
  • Automatic Zero On Start with fresh air sample.
  • SPAN Calibration
  • automatic with calibration gas.
  • Response Time
  • Vlaximum 20 seconds at 95% variation
  • Power Supply
  • Internal battery pack with external charger 220V/50 Hz
  • Working Temperature
  • -5Deg.Cto 55Deg.C
  • Storage Temperature
  • -20Deg.C to45Deg.C
  • Case
  • Aluminum
  • External Dimension
  • 170X100X130 mm
  • Weight
  • 1.5 Kg
  • Probe(optional)
  • (i) 8mm, Dia SS 600 mm length with 2 meter Hose Probes of other material & length available. (ii) Sniffer Probe : To detect & locate the precise position of Gas leak in a pipe network.
  • Accessories
  • Leather case with shoulder strap, battery charger, operational manual.
    Untitled Document