Untitled Document
Untitled Document
Enquiry
Portable Gas Analysers
Products/ Portable-Gas-Analyzers
MOdel 84
Special Features
  • LONG LIFE ZIRCONIUM SENSOR
  • VERY FAST RESPONSE, NO PURGETIME
  • NO REFERENCE GAS REQUIRED
  • HIGH ACCURACY
  • WIDE MEASUREMENT RANGE 1 PPM TO 96%
  • SIMPLETOOPERATE
  • MAINTENANCE FREE
  • automatic & begins with every start up with fresh air aspirated instead of Gas sample.
  • Automatic self check for efficiency calculation :With aspirated fresh air specific percentage efficiency of the selertpd Fuel is displayed as a cherk nn its calculations.
  • Self Supervisory Diagnosis : Continuously checks the status of:   1) Battery Voltage   2) Sample Flow   3) Oxygen Sensor
  • Model 84
    Model FEM 940
  • Sturdy stainless steel sampling probe with extension tubing for ease of measurement.
  • Thermocouple in the tip of probe measures temperature at point of sampling to minimise error.
  • Time tested high suction inbuilt sampling pump acts against draft. Supervisory circuit continuously monitors it against failure.
  • Inline Filter to Inbuilt Moisture & Dust, Disposable easy to replace filter element. Supervisory Diagnostic circuit continuously checks it against choking.
  • Retains the readings till the next sampling.
  • Compact Aluminum Housing
  • Rechargeable Ni-cad battery pack with charger.
  • Maintenance & Spare Parts : Designed for free maintenance operation. Long Life Sensor.
    Combustion efficiency is determined by Oxygen content and temperature of Fuel gases. An excess air (Oxygen) condition reduces the efficiency as it carries away the heat while a deficient air (Oxygen) produces an incomplete i combustion with consequent higher costs and increased polluting emissions.
  • Specifications
    Model FEM 942
    Model FEM 940
    RAnge





    A) Oxygen
    B) Different Temp.
    C) Efficiency
    D)CO
    E) C02 (Calculated)
    Lambda (Calculated)
    0-25% in Stack Gas
    25-1000 deg.C
    0-99.0%

    0-25%

    0-25% in Stack Gas
    25-650 deg.C
    0-99.0%
    0-2000 PPM
    0-25%

    Resolution



    A) Oxygen
    B)CO
    C) Different Temp.
    D) Efficiency
    0.1%

    0.1%
    0.1%
    0.1%
    1PPM
    0.1%
    0.1%
    Display
    Alpha Numeric LCD
    Alpha Numeric LCD
    Fuels



    User Selectable Oil, Coal , Gas
    User Selectable Oil, Coal , Gas
    Sensors

    A) Oxygen
    B) Temperature
    Electrochemical
    Type K Thermocouple
    Electrochemical
    Type K Thermocouple
    Calibration



    Automatic with Fresh
    Air Sample
    Automatic with Fresh
    Air Sample
    Accuracy


    A) Oxygen
    B)Temp.
    C) Efficiency
    +/- 0.25%
    +/- 0.25%
    +/- 0.25%
    +/- 0.25%
    +/- 0.25%
    +/- 0.25%
    Response Time



    Maximum 30Sec.
    at 95% Variation
    Maximum 30Sec.
    at 95% Variation
    Self Diagnosis





    Combustion efficiency test with diagnostic indications
    Combustion efficiency test with diagnostic indications
    Power Supply







    Internal Ni-cad battery pack with external charger 220V 50Hz Ac
    (Optional 110V50H2)
    Internal Ni-cad battery pack with external charger 220V 50Hz Ac
    (Optional 110V50H2)
    Working Temp
    -5deg X to 55 deg.C
    -5deg X to 55 deg.C
    Storage Temp
    -20 deg.C to 50 deg.C
    -20 deg.C to 50 deg.C
    Line Filter
    Replacable Cartridge
    Replacable Cartridge
    Case
    Aluminium
    ABS Plastic
    External Dimension
    170X110X170mm
    222X105X40mm
    Weight
    1 kg approx
    500 gms
    Accessories







    Leather case with shoulder strap Battery charger, Operational Manual
    Leather case with shoulder strap Battery charger, Operational Manual
    Probe Length
    SS600mi m length standard
    (900mm, 1200mm, Optiona i)
    SS600mi m length standard
    (900mm, 1200mm, Optiona i)
    Untitled Document